Share

Agilent 7850 ICP-MS

The Agilent 7850 ICP-MS instrument can handle samples with up to 25% solids, reducing the dilution time trap.

The Agilent 7850 ICP-MS instrument features a Helium mode collision cell and half-mass correction that remove both polyatomic and doubly charged ion interferences, making method development simpler and addressing a common cause of time-wasting sample re-measurement. Free your ICP-MS analysis from common time traps with the Agilent 7850 ICP-MS. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value.​ The 7850 ICP-MS instrument can handle samples with up to 25% solids, reducing the dilution time trap. The instrument features a helium mode collision cell and half mass correction that remove both polyatomic and doubly charged ion interferences, making method development simpler and addressing a common cause of time-wasting sample re-measurement. The 7850’s Ultra High Matrix Introduction system uses an argon stream to dilute samples. Samples with matrix levels up to 25% TDS can be measured without time-consuming and error-prone manual dilutions.

agilent logo
agilent 7850 icp-ms
truck-icon

Need consumables or parts?

Features

  • Standard operating procedures and fully developed methods for regulated and routine methods
  • Ultra High Matrix Introduction (UHMI) reduces sample preparation time
  • Helium collision cell and half-mass correction remove troublesome polyatomic and doubly-charged interferences
  • Measure high matrix samples without having to matrix-match calibration standards
  • Identify unusual sample matrices using IntelliQuant and get a complete elemental profile of each sample
  • Outlier Conditional Formatting (OCF) reduces data review times for busy or inexperienced ICP-MS operators
  • Early Maintenance Feedback (EMF) uses sensors and counters to determine when maintenance is needed
  • Method-specific analyzer packages containing ICP-MS hardware, software, consumables, and documentation
  • Part of Agilent’s best-in-class line-up of ICP-MS instruments: Agilent 7850 ICP-MS, Agilent 7900 ICP-MS, and Agilent 8900 Triple Quadrupole ICP-MS
agilent 7850 icp-ms

Let us help you procure your next great instrument!

Agilent 7850 ICP-MS

Interested in financing? Ask us about our rental, lease, or other flexible financing options!

Level up your lab!

Article

Accurate microplastics analysis requires reliable calibration standards. This article explores the Frontier Labs Microplastics Calibration Standard Set, which offers a comprehensive solution with 12 common polymers, customizable diluents, and easy-to-use glass wool.

Article

Investing in training for your laboratory team not only maximizes the efficiency and accuracy of your advanced analytical instruments but also ensures a safer and more productive work environment. Empower your team with hands-on experience and industry-recognized best practices to foster a culture of excellence and long-term success.
Quantum Analytics Logo

REGISTER FOR LIVE WEBINAR

Agilent 7850 ICP-MS

Complete this form below to sign up and we will reach out to you with instructions