Share

Agilent 1260 Infinity II LC System

Agilent 1260 Infinity II LC system delivers the performance, reliability, and robustness you need for your critical laboratory testing.

The Agilent 1260 Infinity II LC System is a robust high performance liquid chromatography instrument that offers the widest choice of modules for analytical HPLC and entry-level UHPLC. It delivers the performance, reliability, and robustness you need for highest confidence in your daily results.

Building on the history of the 1100 and 1200 series analytical HPLC, the Agilent 1260 Infinity II LC delivers robust HPLC results while providing several ease-of-use features, making it the standard system for routine HPLC testing and analysis. Mix and match new modules with existing HPLC instrumentation to maximize uptime and minimize disruption. The 1260 Infinity II LC puts you on the fast track to efficiency, optimizing speed and resolution for analysis by HPLC.

Delivering pressures up to 600 bar, the Agilent 1260 Infinity II Quaternary Pump is a perfect match for our InfinityLab Poroshell 120 columns. Pulse-free, stable and well-mixed gradients ensure higher sensitivity and more reliable results while the smaller particles achieve faster separations and higher resolution. With access to up to four solvents, you have utmost flexibility in automated solvent blending for a wide range of research and routine applications. Robust materials withstand the most demanding applications and keep the pump running for years, reducing downtime to a minimum and lowering operating costs. The Agilent 1260 Infinity II LC gives you unmatched flexibility to handle multiple sample containers. Simply exchange a sample tray or an entire drawer in the easy-to-access Multisampler, and submit your samples for analysis through the intuitive graphical software interface. Hundreds or even thousands of samples can be processed – with no manual interaction. The Multisampler’s unique dual-needle option allows you to perform sample-handling steps in parallel to analyses of other samples, reducing overall analysis cycle times significantly.

agilent logo
agilent 1260
truck-icon

Need consumables or parts?

Features

  • Compatible with conventional and ultrahigh performance LC: 1260 Infinity II Quaternary Pump and 1260 Infinity Binary Pump operate up to 600 bar, a perfect match for our InfinityLab Poroshell 120 columns
  • Analytical and semipreparative purifications: wide flow range of the 1260 Infinity II Quaternary Pump (up to 10 mL/min) perfectly supports standard and semipreparative applications
  • Fast and precise gradients: 1260 Infinity II Binary Pump is the perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems
  • Ultralow carryover: multiwash capability of the 1260 Infinity II Multisampler cleans all relevant injection parts between runs, flushing the injection needle outside with three solvents using seat backflush procedures to reduce carryover to less than 10 ppm
  • Reduced cycle times: with the unique Agilent dual-needle design, run samples alternately through one or the other injection path. Can reduce cycle times to mere seconds, virtually eliminating conventional wait times – whether for large volume loadings or flushing procedures
  • Efficient sample handling and logistics: using shallow well-plate drawers, 1260 Infinity II Multisampler takes a maximum load of 16 microtiter plates and up to 6,144 samples – the most of any single system
  • Efficient column handling and temperature control: 1260 Infinity II Multicolumn Thermostat holds up to four columns with direct access to each column through a Quick-Change switching valve, delivering flexibility and eliminating the need to disconnect and reconnect columns
  • Higher quality data: 1260 Infinity II Diode Array Detector HS delivers lower detection limits and higher data quality for more confidence
  • Efficient control, acquisition, and reporting: Agilent instrument control framework (ICF) enables smooth control of Agilent LC instrumentation through third-party chromatography data systems
agilent 1260

Let us help you procure your next great instrument!

Agilent 1260 Infinity II LC System

Interested in financing? Ask us about our rental, lease, or other flexible financing options!

Level up your lab!

Article

Accurate microplastics analysis requires reliable calibration standards. This article explores the Frontier Labs Microplastics Calibration Standard Set, which offers a comprehensive solution with 12 common polymers, customizable diluents, and easy-to-use glass wool.

Article

Investing in training for your laboratory team not only maximizes the efficiency and accuracy of your advanced analytical instruments but also ensures a safer and more productive work environment. Empower your team with hands-on experience and industry-recognized best practices to foster a culture of excellence and long-term success.
Quantum Analytics Logo

REGISTER FOR LIVE WEBINAR

Agilent 1260 Infinity II LC System

Complete this form below to sign up and we will reach out to you with instructions